Media 000388080: Skull
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000388080
Media type
Mesh
Object element or part
skull
Object represented
Object taxonomy
Phoenicopterus chilensis
Side
--
Orientation
--
Short description
.stl
Full description
--
Creator
Baumgart, Stephanie
Date created
September 30, 2021
Date uploaded
October 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
FMNH_B_398896_Phoenicopterus_skull.stl
File format(s)
STL
File size
584 MB
Points
6104712
Polygons
12256045
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
41.304, 167.444, 73.768
Centroid coordinates
19.621, 91.856, 45.603
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Field Museum of Natural History provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Birds:398896 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Coldren, Daryl
Event date
May 26, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
110
Power
0.022
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000371793: Skull [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Coldren, Daryl
Event date
June 20, 2021
Software
VGStudio Max 3.3
Description
calibrated histogram to highest and lowest densities, cropped ROI down to the specimen
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000371793: Skull [CTImageSeries] [CT] was processed to create derived Media 000388080: Skull [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Baumgart, Stephanie
Event date
September 30, 2021
Software
Materialise Mimics 23.0
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000388080: Skull [Mesh] [CT] (this media)