GENERAL DETAILS Field Definitions
Media ID
000389095
Media type
Volumetric Image Series
Object element or part
pes
Object represented
Object taxonomy
Equus caballus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Laurel R. Yohe
Date created
August 06, 2019
Date uploaded
October 05, 2021
FILE OBJECT DETAILS Field Definitions
File name
NS293_horse_forelimb_iodine.zip
File format(s)
ZIP archive, TIFF
File size
1.37 GB
Image width
514
Image height
873
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.073581
Y pixel spacing
0.073581
Z pixel spacing
0.073581
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,940
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Chemical and Biophysical Instrumentation Center (Yale University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
National Science Foundation
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
L-NS:MAMM:NS293
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Chemical and Biophysical Instrumentation Center (Yale University)
Creator
Laurel R. Yohe
Event date
August 06, 2019
Software
Nikon
Description
pes of forelimb stained with 10% Lugol's iodine
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
1
Projections
3141
Voltage
81
Power
--
Amperage
66
Surrounding material
plastic bag in plastic jar
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
.2
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
317.9169
Source detector distance
864.1305
Target material
molybdenum
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000389095: Pes [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Nikon
Description
Dual, high quality
Media produced by this event on MorphoSource
Media 000389095: Pes [CTImageSeries] [CT] (this media)