Media 000391004: Juvenile Skeleton
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000391004
Media type
Volumetric Image Series
Object element or part
Juvenile skeleton
Object represented
Object taxonomy
Chamaeleo calyptratus
Side
--
Orientation
--
Short description
zipped 16 bit tiff stack
Full description
juvenile, Al calibration
Creator
Gage, Matt
Date created
October 14, 2021
Date uploaded
October 15, 2021

FILE OBJECT DETAILS Field Definitions

File name
YPM-Herr-22241_Chamaeleo_calyptratus_Rec.zip
File format(s)
ZIP archive, TIFF
File size
3.47 GB
Image width
2240
Image height
224
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.019457
Y pixel spacing
0.019457
Z pixel spacing
0.019457
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,237

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale University
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; overt TCN; NSF DBI-1701769; NSF DBI-1702263
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM HERR 022241 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Gage, Matt
Event date
October 14, 2021
Software
NRecon
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.350
Flux normalization
No
Pixel spacing calibration
Geometry
Shading correction
No
Frame averaging
3
Projections
857
Voltage
40
Power
--
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000391004: Juvenile Skeleton [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Gage, Matt
Event date
October 14, 2021
Software
Bruker NRecon
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000391004: Juvenile Skeleton [CTImageSeries] [CT] (this media)