Media 000392156: Cervical Vertebra
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000392156: Cervical Vertebra
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000392156
Media type
Mesh
Object element or part
Cervical Vertebra
Object represented
Object taxonomy
Python bivittatus
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Edward Stanley
Date created
--
Date uploaded
October 21, 2021
FILE OBJECT DETAILS Field Definitions
File name
Python_bivittatus_UF-H-167549.obj
File format(s)
OBJ
File size
1.37 MB
Points
15239
Polygons
30474
Map type
Color
UV coordinates
False
Vertex color
False
Bounding box dimensions
13.722, 27.024, 15.057
Centroid coordinates
-0.482, -6.975, 70.036
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:167549
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
Datos|X A
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1600
Voltage
120kV
Power
24W
Amperage
200µA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000392156: Cervical Vertebra [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
Datos|X R
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000392156: Cervical Vertebra [Mesh] [CT] (this media)