Media 000393745: Chevron
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000393745
Media type
Mesh
Object element or part
Chevron
Object represented
Object taxonomy
Borealestes serendipitus
Side
--
Orientation
--
Short description
Chevron, part of NMS.G.1992.47.121.1.1
Full description
This media represents a part of the specimen NMS:G:1992.47.121. The part is a chevron and is additionally identified as NMS:G:1992.47.121.8.
Creator
Elsa Panciroli
Date created
November 02, 2021
Date uploaded
November 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
Borealestes.serendiptus_NMS_G.1992.47.121.8_Chevron.stl
File format(s)
STL
File size
3.39 MB
Points
35464
Polygons
70996
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1808.635, 1326.138, 3151.597
Centroid coordinates
6726.877, 5230.080, 4790.532
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom Make microCT Scanner Assembled In-House, School of Geosciences (University of Edinburgh)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object NMS:G:1992.47.121 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Custom Make microCT Scanner Assembled In-House
Device facility
School of Geosciences (University of Edinburgh)
Creator
Ian Butler/Elsa Panciroli
Event date
--
Software
--
Description
CT scan slices of NMS.G.1992.47.121.1.8, chevron
Description attachment
None
Reference attachment
None
Exposure time
2
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
n.a
Projections
2000
Voltage
70
Power
2.8
Amperage
40
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000393679: Ct Scan Slices Of Nms.G.1992.47.121.1.8 [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Ian Butler/Elsa Panciroli
Event date
--
Software
--
Description
CT scan slices of NMS.G.1992.47.121.1.8
Description attachment
None

Processing Activity 2: Transform: Reflection

Software
Avizo
Description

STEP 3: IMAGE PROCESSING

Derived Media 000393679: Ct Scan Slices Of Nms.G.1992.47.121.1.8 [CTImageSeries] [CT] was processed to create derived Media 000393745: Chevron [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Elsa Panciroli
Event date
--
Software
Mimics
Description
Chevron
Description attachment
None

Media produced by this event on MorphoSource

Media 000393745: Chevron [Mesh] [CT] (this media)