Media 000393759: Head
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000393759
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Tadarida brasiliensis
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Laurel Yohe
Date created
August 19, 2019
Date uploaded
November 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
Yohe_DR028_Tadarida_brasiliensis_01_TIFF0000.zip
File format(s)
ZIP archive, TIFF
File size
5.13 GB
Image width
1722
Image height
1426
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.011572
Y pixel spacing
0.011572
Z pixel spacing
0.011572
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,382

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Chemical and Biophysical Instrumentation Center (Yale University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object L-LD:DR028 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Chemical and Biophysical Instrumentation Center (Yale University)
Creator
Laurel Yohe
Event date
August 19, 2019
Software
Nikon
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
1
Projections
--
Voltage
80
Power
--
Amperage
68
Surrounding material
agarose in falcon tube
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
--
Detector pixels Y
2000
Detector pixels size Y
--
Detector configuration
--
Source object distance
49.99948
Source detector distance
864.1334
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000393759: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Laurel Yohe
Event date
February 07, 2014
Software
Nikon
Description
bat head in iodine
Description attachment
None

Media produced by this event on MorphoSource

Media 000393759: Head [CTImageSeries] [CT] (this media)