Media 000397324: Dome [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000397324
Media type
CTImageSeries
Object element or part
dome
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: UCMP130051hires: Scans of a pachycephalosaur dome (UCMP 130051; Judith River Fm., Campanian, Hill Co., Montana) for Mark Goodwin of the University of California at Berkeley. Specimen scanned by Matthew Colbert 16 October 2015. 16bit: Scan parameters: NSI scanner. GE Titan source, small spot, 450 kV, 0.5 mA, 2 brass filters, Perkin Elmer detector, 0.5 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 759 mm, source to detector 1486.209 mm, continuous CT scan, no frames averaged, 0 skip frames, 2088 projections, 4 gain calibrations, 15 mm calibration phantom, data range [-4, 22.5] (rescaled from NSI default). Voxel size = 0.1034 mm, beam-hardening correction = 0.4. Total slices = 1875.
Creator
Matthew Colbert
Date created
October 16, 2015
Date uploaded
November 19, 2021

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
4.04 GB
Image width
1276
Image height
1088
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.103400
Y pixel spacing
0.103400
Z pixel spacing
0.103400
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,875

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Restricted Download
IP holder
University of California Regents; University of California Museum of Paleontology
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1053370, the Doris O. and Samuel P. Welles Research Fund, and NSF DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, originally appearing in ?, with data collection funded by NSF EAR-1053370 and the Doris O. and Samuel P. Welles Research Fund and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:130051 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
October 16, 2015
Software
--
Description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: UCMP130051hires: Scans of a pachycephalosaur dome (UCMP 130051; Judith River Fm., Campanian, Hill Co., Montana) for Mark Goodwin of the University of California at Berkeley. Specimen scanned by Matthew Colbert 16 October 2015. 16bit: Scan parameters: NSI scanner. GE Titan source, small spot, 450 kV, 0.5 mA, 2 brass filters, Perkin Elmer detector, 0.5 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 759 mm, source to detector 1486.209 mm, continuous CT scan, no frames averaged, 0 skip frames, 2088 projections, 4 gain calibrations, 15 mm calibration phantom, data range [-4, 22.5] (rescaled from NSI default). Voxel size = 0.1034 mm, beam-hardening correction = 0.4. Total slices = 1875.
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2088
Voltage
450
Power
--
Amperage
0.5
Surrounding material
--
Xray tube type
GE Titan
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000397324: Dome [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000397324: Dome [CTImageSeries] [CT] (this media)