Media 000397335: Dome [CTImageSeries] [CT]
Represents:
Biological Specimen

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000397335
Media type
CTImageSeries
File format(s)
image/tiff
File size
2,100,692,934 bytes
Object element or part
dome
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: AMNH5450: Scan of a dome of Ornatotholus browni (AMNH5450; Late Cretaceous Dinosaur Park Fm, Alberta Canada; Collected by Barnum Brown, 1913) for Mark Goodwin of The University of California at Berkeley. Includes data with gray scales adjusted from NSI defaults, and with values unchanged from NSI default values. Specimen scanned by Matthew Colbert 8 January 2015. 16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 200 kV, 0.16 mA, no filter, Perkin Elmer detector, 1.0 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 245.558 mm, source to detector 1126 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-10, 177] (grayscale range adjusted from NSI defaults), [-18.290285 762.162048] (NSI default grayscales), beam-hardening correction = 0.5. Voxel size = 0.0464 mm. Total slices = 1870.
Creator
Matthew Colbert
Date created
January 08, 2015
Date uploaded
November 19, 2021
Image width
1076
Image height
620
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.0464
Y pixel spacing
0.0464
Z pixel spacing
0.0464
Number of images in set
1,870

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging N/R, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
American Museum of Natural History
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF EAR-1053370, the Doris O. and Samuel P. Welles Research Fund, and NSF DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, originally appearing in ?, with data collection funded by NSF EAR-1053370 and the Doris O. and Samuel P. Welles Research Fund and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:farb:5450 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging N/R
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
2015-01-08
Software
--
Description
University of Texas High-Resolution X-ray CT Facility Archive Goodwin: AMNH5450: Scan of a dome of Ornatotholus browni (AMNH5450; Late Cretaceous Dinosaur Park Fm, Alberta Canada; Collected by Barnum Brown, 1913) for Mark Goodwin of The University of California at Berkeley. Includes data with gray scales adjusted from NSI defaults, and with values unchanged from NSI default values. Specimen scanned by Matthew Colbert 8 January 2015. 16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 200 kV, 0.16 mA, no filter, Perkin Elmer detector, 1.0 pF gain, 1 fps (999.911 ms integration time), no binning, no flip, source to object 245.558 mm, source to detector 1126 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-10, 177] (grayscale range adjusted from NSI defaults), [-18.290285 762.162048] (NSI default grayscales), beam-hardening correction = 0.5. Voxel size = 0.0464 mm. Total slices = 1870.
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
3600
Voltage
200
Power
--
Amperage
160
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000397335: Dome [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000397335: Dome [CTImageSeries] [CT] (this media)