Media 000397404: L1 Vertebra
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000397404: L1 Vertebra
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS
Media ID
000397404
Media type
Mesh
Object element or part
L1 vertebra
Object represented
Object taxonomy
Australopithecus sediba
Object organization
Side
--
Orientation
--
Short description
MH 2 partial L1 vertebra
Full description
--
Creator
--
Date created
--
Date uploaded
November 19, 2021
FILE OBJECT DETAILS
File format(s)
application/stl
File size
6.97 MB
Points
73051
Polygons
146094
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
20.516, 8.160, 15.903
Centroid coordinates
181.996, 60.940, 182.999
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225/320 LC, Microfocus X-ray Computed Tomography (CT) facility of the Palaeosciences Centre (University of the Witwatersrand)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
na:U.W 88-281
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225/320 LC
Device facility
Microfocus X-ray Computed Tomography (CT) facility of the Palaeosciences Centre (University of the Witwatersrand)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000397404: L1 Vertebra [Mesh] [CT] (this media).
Processing Details
Creator
--
Date processed
--
Software
--
Description
--
Description attachment
None