Media 000398462: Cranium
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000398462
Media type
Mesh
Object element or part
Cranium
Object represented
Object taxonomy
Sternotherus odoratus
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Guilherme Hermanson
Date created
November 26, 2021
Date uploaded
November 26, 2021

FILE OBJECT DETAILS Field Definitions

File name
Sternotherus_odoratus_YPMVZ_019736.ply
File format(s)
PLY
File size
40.6 MB
Points
968364
Polygons
1932632
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
60.053, 37.100, 21.601
Centroid coordinates
35.465, 22.291, 39.701
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Yale University
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM HERR 019736.001 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1440
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000072565: Head [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Zachary Randall
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000072565: Head [CTImageSeries] [Etc] was processed to create derived Media 000398462: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Guilherme Hermanson
Event date
--
Software
Avizo
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000398462: Cranium [Mesh] [CT] (this media)