Media 000399624: Dissected Vertebral Column, Trunk Section (Micro) [CTImageSeries] [CT]
Represents:
Biological Specimen
Not in Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000399624
Media type
CTImageSeries
File format(s)
image/bmp
File size
350,725,713 bytes
Object element or part
Dissected vertebral column, trunk section (micro)
Side
--
Orientation
--
Short description
Dissected vertebral column, trunk section (micro)
Full description
This scan includes the vertebral column from the trunk region dissected out from the body. Vertebrae are from the body region approximately between the pectoral girdle and dorsal fin. The scan includes four whole vertebrae.
Creator
3D Anatomy Studios
Date created
September 15, 2021
Date uploaded
December 01, 2021
Image width
808
Image height
808
Color space
--
Color depth
8
Compression
BI_RGB
Series type
Reconstructed image stack
X pixel spacing
0.0261
Y pixel spacing
0.0261
Z pixel spacing
0.0261
Pixel spacing units
Mm
Slice thickness
0.026
Number of images in set
1,506

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1276, Keck XROMM Core Facility (Brown University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
We thank the Keck XROMM Core Facility (Brown University) for their donation of scanning time.
Publisher
3D Anatomy Studios
Cite as
3D Anatomy Studios (2021). CT scan of a spiny dogfish shark (Squalus acanthias) purchased from Carolina Biological Supply, ID 3DAS-ID00002 (published BMP files). Retrieved from MorphoSource ARK: [Insert ARK link].
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object 3DAS:00002 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1276
Device facility
Keck XROMM Core Facility (Brown University)
Creator
3D Anatomy Studios
Date
2021-09-15
Software
Skyscan v1.5
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
262
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
ON (2)
Projections
259
Voltage
60
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
59.572
Source detector distance
159.149
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000399624: Dissected Vertebral Column, Trunk Section (Micro) [CTImageSeries] [CT] (this media).

Processing Details

Creator
3D Anatomy Studios
Date processed
2021-09-15
Software
SkyScan v1.5
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000399624: Dissected Vertebral Column, Trunk Section (Micro) [CTImageSeries] [CT] (this media)