Media 000399631: Bidenichthys Okamotoi Full Body Micro Ct
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

Media preview currently unavailable. Please check back later.

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000399631
Media type
Volumetric Image Series
Object element or part
Bidenichthys okamotoi full body micro-CT
Object represented
Object taxonomy
Bidenichthys okamotoi
Side
--
Orientation
Transversal
Short description
--
Full description
--
Creator
Lauridsen, Henrik
Date created
December 30, 2020
Date uploaded
December 01, 2021

FILE OBJECT DETAILS Field Definitions

File name
Bidenichthys okamotoi_micro-CT_82umIso_FullBody.zip
File format(s)
ZIP archive
File size
1.5 GB
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.082000
Y pixel spacing
0.082000
Z pixel spacing
0.082000
Pixel spacing units
--
Slice thickness
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical XtremeCT, Aarhus Department of Clinical Medicine (Aarhus University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zmuc:p:2397717 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical XtremeCT
Device facility
Aarhus Department of Clinical Medicine (Aarhus University)
Creator
Lauridsen, Henrik
Event date
December 29, 2020
Software
Scanco user software
Description
a Scanco Medical XtremeCT system
Description attachment
None
Reference attachment
None
Exposure time
1000 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1000
Voltage
59.4kVp
Power
--
Amperage
90 microA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000399631: Bidenichthys Okamotoi Full Body Micro Ct [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Lauridsen, Henrik
Event date
December 30, 2020
Software
ImageJ
Description
Two acquisitions each covering half of the specimen were concatenated in ImageJ
Description attachment
None

Media produced by this event on MorphoSource

Media 000399631: Bidenichthys Okamotoi Full Body Micro Ct [CTImageSeries] [CT] (this media)