Media 000405007: Forelimbs [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000405007
Media type
CTImageSeries
File format(s)
image/tiff
File size
2,404,393,589 bytes
Object element or part
Forelimbs
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
December 06, 2021
Image width
1856
Image height
789
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.0336075
Y pixel spacing
0.0336075
Z pixel spacing
0.0336075
Pixel spacing units
Mm
Number of images in set
1,094

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-202368 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
2000
Voltage
115
Power
13.8
Amperage
120
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 3 activities to create derived Media 000405007: Forelimbs [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Processing Activity 2: Crop

Software
ImageJ
Description

Processing Activity 3: Transform: Reflection

Software
ImageJ
Description

Media produced by this event on MorphoSource


Media 000405007: Forelimbs [CTImageSeries] [CT] (this media)