Media 000405907: Trematomus Scotti (Tsco 2018 009), Micro Ct (Iodine Stained), Whole Specimen [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000405907
Media type
CTImageSeries
Object element or part
Trematomus scotti (Tsco_2018_009), microCT (iodine stained), Whole specimen
Side
--
Orientation
Transversal
Short description
microCT scan of full iodine stained specimen of Trematomus scotti (Tsco_2018_009) with X-cell xenomas
Full description
--
Creator
Lauridsen, Henrik
Date created
February 26, 2021
Date uploaded
December 08, 2021
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
723 MB
Image width
579
Image height
468
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.082000
Y pixel spacing
0.082000
Z pixel spacing
0.082000
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,716
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical XtremeCT, Aarhus Department of Clinical Medicine (Aarhus University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zmuc:p:241300
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Scanco Medical XtremeCT
Device facility
Aarhus Department of Clinical Medicine (Aarhus University)
Creator
Lauridsen, Henrik
Date
February 26, 2021
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
132
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1000
Voltage
59.4
Power
--
Amperage
119
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000405907: Trematomus Scotti (Tsco 2018 009), Micro Ct (Iodine Stained), Whole Specimen [CTImageSeries] [CT]
(this media).
Processing Details
Creator
Lauridsen, Henrik
Date processed
February 26, 2021
Software
ImageJ
Description
Exported DICOM to TIF stack
Description attachment
None
Media produced by this event on MorphoSource
Media 000405907: Trematomus Scotti (Tsco 2018 009), Micro Ct (Iodine Stained), Whole Specimen [CTImageSeries] [CT] (this media)