Media 000407013: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000407013: Whole Body
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000407013
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Sphoeroides annulatus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Sphoeroides annulatus slice data
Creator
Troyer, Emily
Date created
August 11, 2021
Date uploaded
December 10, 2021
FILE OBJECT DETAILS Field Definitions
File name
Image_Series_Sphoeroides_annulatus.zip
File format(s)
ZIP archive, JPEG
File size
5.27 MB
Image width
555
Image height
691
Color space
YCbCr
Color depth
8
Compression
JPEG
Series type
Reconstructed image stack
X pixel spacing
0.035500
Y pixel spacing
0.035500
Z pixel spacing
0.035500
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,507
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UWFC:ADULT COLLECTION:UW 022574
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Troyer, Emily
Event date
August 11, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1700
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
50
Power
--
Amperage
160
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000407013: Whole Body [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
NRecon
Description
Media produced by this event on MorphoSource
Media 000407013: Whole Body [CTImageSeries] [CT] (this media)