Media 000408278: Pelvis
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

No collections found.

GENERAL DETAILS Field Definitions

Media ID
000408278
Media type
Mesh
Object element or part
Pelvis
Object taxonomy
Agamodon anguliceps
Side
--
Orientation
--
Short description
--
Full description
--
Creator
S. Swank
Date created
December 17, 2021
Date uploaded
December 17, 2021

FILE OBJECT DETAILS Field Definitions

File name
Aa.263899.375.ply
File format(s)
PLY
File size
38.4 MB
Points
846991
Polygons
861394
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
12.927, 9.938, 9.658
Centroid coordinates
9.985, -7.529, 4.269
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2, LUC Department of Biology (Loyola University Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DEB-1456462
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:263899 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2
Device facility
LUC Department of Biology (Loyola University Chicago)
Creator
S. Swank
Event date
December 17, 2021
Software
InVesalius 3.1; MeshLab 2020.12
Description
description
Description attachment
None
Reference attachment
None
Exposure time
4 min
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65-70 kV
Power
--
Amperage
100-114 mA
Surrounding material
Plastic bag
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000408278: Pelvis [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Sam Swank
Event date
December 06, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Photos to Mesh

Software
InVesalius
Description
created .ply file using a manual threshold

Media produced by this event on MorphoSource

Media 000408278: Pelvis [Mesh] [CT] (this media)