Media 000408368: Dicect Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000408368
Media type
Volumetric Image Series
Object element or part
DICECT-whole-body
Object represented
Object taxonomy
Sechellophryne gardineri
Side
--
Orientation
--
Short description
Stained with 1.25% Lugol's solution
Full description
--
Creator
Jaimi Gray
Date created
November 30, 2021
Date uploaded
December 18, 2021

FILE OBJECT DETAILS Field Definitions

File name
YPM-her-A-1703-diceCT.zip
File format(s)
ZIP archive, TIFF
File size
776 MB
Image width
994
Image height
1035
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.008254
Y pixel spacing
0.008254
Z pixel spacing
0.008254
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,294

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object YPM:VZ:YPM HERA 001703 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Event date
November 30, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000408368: Dicect Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Jaimi Gray
Event date
November 30, 2021
Software
GE reconstruction software and VG Studio Max
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000408368: Dicect Whole Body [CTImageSeries] [CT] (this media)