Media 000408929: Calcaneus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000408929
Media type
Mesh
Object element or part
Calcaneus
Object represented
Object taxonomy
Eulemur mongoz
Object organization
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Olivia Di Iorio
Date created
December 03, 2021
Date uploaded
December 21, 2021

FILE OBJECT DETAILS Field Definitions

File name
DLC5952f_Eulemur_mongoz_calcaneus_geo.stl
File format(s)
STL
File size
3.19 MB
Points
6176
Polygons
12348
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.733, 8.241, 19.197
Centroid coordinates
10.813, 5.344, 10.979
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Duke Lemur Center
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:5952f was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
1800
Voltage
150
Power
--
Amperage
155
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000169917: Feet [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
Gabriel Yapuncich
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000169917: Feet [CTImageSeries] [CT] was processed with 2 activities to create derived Media 000408929: Calcaneus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Olivia Di Iorio
Event date
December 03, 2021
Software
Geomagic
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Processing Activity 2: Smoothing/Noise Reduction

Software
Geomagic
Description

Media produced by this event on MorphoSource

Media 000408929: Calcaneus [Mesh] [CT] (this media)