Media 000409705: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000409705: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000409705
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Testudo horsfieldii
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
December 23, 2021
Date uploaded
December 23, 2021
FILE OBJECT DETAILS Field Definitions
File name
Testudo_horsfieldii_OUMNH_10344_Mandiible.ply
File format(s)
PLY
File size
4.66 MB
Points
111037
Polygons
222310
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22964.078, 19182.605, 11485.777
Centroid coordinates
65446.288, 13017.063, 51006.964
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Oxford University Museum of Natural History (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
oumnh:zc:10344
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Benson, Roger
Event date
June 25, 2019
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
267 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
217 kV
Power
--
Amperage
318 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000354235: Full Body [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Benson, Roger
Event date
June 25, 2019
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000354235: Full Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000409705: Mandible [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Serjoscha Evers
Event date
--
Software
Mimics
Description
--
Description attachment
None
Media produced by this event on MorphoSource