Media 000409747: Mandible
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000409747
Media type
Mesh
Object element or part
Mandible
Object taxonomy
Kinosternon subrubrum hippocrepis
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
December 23, 2021
Date uploaded
December 23, 2021

FILE OBJECT DETAILS Field Definitions

File name
Kinosternon_subrubrum_hippocrepis_FMNH211711_Mandible.ply
File format(s)
PLY
File size
77.4 MB
Points
1830039
Polygons
3700197
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
18.862, 17.334, 9.654
Centroid coordinates
13.472, 16.860, 43.409
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:211711 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch Neander
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1600
Voltage
80
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000077404: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
April Isch Neander
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000077404: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000409747: Mandible [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Serjoscha Evers
Event date
--
Software
Mimics
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000409747: Mandible [Mesh] [CT] (this media)