Media 000409995: Talus [Mesh] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000409995
Media type
Mesh
Object element or part
Talus
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Olivia Di Iorio
Date created
December 03, 2021
Date uploaded
December 27, 2021

FILE OBJECT DETAILS

File format(s)
application/stl
File size
3.03 MB
Points
5,812
Polygons
11,620
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.752, 17.339, 13.573
Centroid coordinates
-8.011, 11.843, 5.218
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Duke Lemur Center
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:6143m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
135
Power
0.045090000000000005
Amperage
334
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000034548: Foot [CTImageSeries] [Etc] .

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000034548: Foot [CTImageSeries] [Etc] was processed with 2 activities to create derived Media 000409995: Talus [Mesh] [CT] (this media).

Processing Details

Creator
Olivia Di Iorio
Date processed
December 03, 2021
Software
Geomagic
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Processing Activity 2: Smoothing/Noise Reduction

Software
Geomagic
Description

Media produced by this event on MorphoSource


Media 000409995: Talus [Mesh] [CT] (this media)