Media 000411209: Humerus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000411209
Media type
Mesh
Object element or part
humerus
Object represented
Object taxonomy
Cebupithecia sarmientoi
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Doug Boyer
Date created
January 06, 2022
Date uploaded
January 06, 2022

FILE OBJECT DETAILS Field Definitions

File name
UCMP38762_Cebupithecia_R-humerus.ply
File format(s)
PLY
File size
321 MB
Points
4148440
Polygons
8297078
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
21.376, 23.376, 89.343
Centroid coordinates
11.303, 14.530, 42.927
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (4 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
University of California Regents; University of California Museum of Paleontology
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
--
Cite as
--
Media preview mode
--
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:38762 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
3142
Voltage
155
Power
--
Amperage
150
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 3 activities to create derived Media 000410747: Humerus [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Processing Activity 2: Crop

Software
Image J
Description

Processing Activity 3: Transform: Reflection

Software
Image J
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000410747: Humerus [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000411209: Humerus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Doug Boyer
Event date
January 06, 2022
Software
avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
avizo
Description

Media produced by this event on MorphoSource

Media 000411209: Humerus [Mesh] [CT] (this media)