Media 000411657: Jaw Fragment
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000411657: Jaw Fragment
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000411657
Media type
Volumetric Image Series
Object element or part
Jaw Fragment
Object represented
Object taxonomy
Macrotarsius jepseni
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
January 07, 2022
FILE OBJECT DETAILS Field Definitions
File name
Aguilar_YPM_VPPU_016431_frag_C_cropflip_.zip
File format(s)
ZIP archive, TIFF
File size
1.58 GB
Image width
856
Image height
721
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.010113
Y pixel spacing
0.010113
Z pixel spacing
0.010113
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,696
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS 1317525 (to DM Boyer and ER Seiffert), 1552848 (to DM Boyer) and Duke University Trinity College of Arts and Sciences
Publisher
Yale Peabody Museum of Natural History
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ypm:vp:ypm vppu 016431
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
110
Power
14.3
Amperage
130
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 3 activities
to create
derived
Media 000411657: Jaw Fragment [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Description
Processing Activity 2: Crop
Software
Image J
Description
Processing Activity 3: Transform: Reflection
Software
Image J
Description
Media produced by this event on MorphoSource
Media 000411657: Jaw Fragment [CTImageSeries] [CT] (this media)