Media 000413003: Trunk Vertebrae [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
Interactive/Embeddable Media Preview is currently unavailable. Please check back later.
2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000413003
Media type
Mesh
File format(s)
application/octet-stream
File size
--
Object element or part
trunk vertebrae
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Jaimi Gray
Date created
January 12, 2022
Date uploaded
January 12, 2022
Points
--
Polygons
--
Map type
--
UV coordinates
--
Vertex color
--
Bounding box dimensions
--
Centroid coordinates
--
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620 Versa x-ray microscope (xrm), UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Amphibians and Reptiles:178534
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 620 Versa x-ray microscope (xrm)
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Date
2021-12-22
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000412859: Whole Body [CTImageSeries] [CT]
.
Processing Details
Creator
Jaimi Gray
Date processed
2021-12-22
Software
GE Reconstruction Software and VG Studio Max
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000412859: Whole Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000413003: Trunk Vertebrae [Mesh] [CT]
(this media).
Processing Details
Creator
Jaimi Gray
Date processed
2022-01-12
Software
VG Studio Max
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000413003: Trunk Vertebrae [Mesh] [CT] (this media)