Media 000414402: Femur, Pelvis [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000414402
Media type
CTImageSeries
File format(s)
application/dicom
File size
72.6 MB
Object element or part
Femur; Pelvis
Side
--
Orientation
--
Short description
--
Full description
--
Creator
S. Swank
Date created
April 08, 2021
Date uploaded
January 15, 2022
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.036000
Y pixel spacing
0.036000
Z pixel spacing
0.036000
Pixel spacing units
Mm
Slice thickness
0.0359999985
Number of images in set
269

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2, LUC Department of Biology (Loyola University Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DEB-1456462
Publisher
Museum of Comparative Zoology, Harvard University
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:R-184018 was imaged to create this media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Perkin Elmer Quantum GX2
Device facility
LUC Department of Biology (Loyola University Chicago)
Creator
S. Swank
Date
2021-04-08
Software
MeshLab 2020.12; InVesalius 3.1
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
4 min
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65-70 kV
Power
--
Amperage
100-114 mA
Surrounding material
Plastic bag
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource


Media 000414402: Femur, Pelvis [CTImageSeries] [CT] (this media)