Media 000416088: Skull [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000416088
Media type
CTImageSeries
Object element or part
skull
Side
--
Orientation
--
Short description
HRXCT scan - partial skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0031 Folders cifelli/kenn: Kennalestes gobiensis, Djadokha formation, Bayn Dzak, Gobi Desert, Mongonlia. ZPAL MGM-I/1. Scanned for Rich Cifelli of the University of Oklahoma. 8bit and 16bit: Scanning done by Richard Ketcham on 5/7/98. II, 180 kV, 0.133 mA, no filter, air wedge, 160% offset, slice thickness 0.061 mm, S.O.D. 25.5 mm, 1800 views, 2 samples per view, interslice spacing 0.05 mm, field of reconstruction 13 mm, recon. offset -800, recon. scale 10. Done in 2 passes using 3-slice mode.
Creator
--
Date created
May 07, 1998
Date uploaded
January 25, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
14.8 MB
Image width
418
Image height
429
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.025000
Y pixel spacing
0.025000
Z pixel spacing
0.050000
Pixel spacing units
Mm
Slice thickness
0.061
Number of images in set
462

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Zoological Institute of Paleobiology, Polish Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Prohibited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, with data collection funded by Richard Cifelli and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zpal:v.39:MGM-I/1 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000416088: Skull [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000416088: Skull [CTImageSeries] [CT] (this media)