Media 000416601: Cranium [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000416601
Media type
CTImageSeries
Object element or part
cranium
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Kraatz, Brian
Date created
February 01, 2014
Date uploaded
January 25, 2022

FILE OBJECT DETAILS

File format(s)
application/dicom
File size
238 MB
Image width
--
Image height
--
Color space
MONOCHROME2
Color depth
--
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.125000
Y pixel spacing
0.125000
Z pixel spacing
0.125000
Pixel spacing units
Mm
Slice thickness
0.125
Number of images in set
641

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100, College of Dental Medicine (Western University of Health Sciences)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
Western University of Health Sciences
Publisher
Kraatz, Brian
Cite as
Originally appearing in Kraatz & Sherratt 2016 PeerJ 4:e2453, the collection of which was funded by Western University of Health Sciences
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-33614 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100
Device facility
College of Dental Medicine (Western University of Health Sciences)
Creator
Kraatz, Brian
Date
February 01, 2014
Software
--
Description
CT scan of cranium
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
Cu 0.2mm
Exposure time
9.3
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
75
Power
--
Amperage
3
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000416601: Cranium [CTImageSeries] [CT] (this media).

Processing Details

Creator
Kraatz, Brian
Date processed
February 01, 2014
Software
i-Dixel
Description
Volumetric reconstruction
Description attachment
None

Media produced by this event on MorphoSource


Media 000416601: Cranium [CTImageSeries] [CT] (this media)