Media 000416854: M2
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000416854: M2
Open Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000416854
Media type
Volumetric Image Series
Object element or part
M2
Object represented
Object taxonomy
Taxonomy indet.
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Ferreira, Gabriel
Date created
January 25, 2022
Date uploaded
January 26, 2022
FILE OBJECT DETAILS Field Definitions
File name
GPIT-86051-Parelasmotherium-M2.zip
File format(s)
ZIP archive, PNG
File size
2.13 GB
Image width
2549
Image height
2152
Color space
--
Color depth
--
Compression
Deflate; Deflate/Inflate
X pixel spacing
0.050027
Y pixel spacing
0.050027
Z pixel spacing
0.050027
Pixel spacing units
--
Slice thickness
--
Number of images in set
2,715
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon HT X 320, Centre for Visualization, Digitization and Replication (VDR) (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
gpit:PV-86051
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon HT X 320
Device facility
Centre for Visualization, Digitization and Replication (VDR) (Eberhard Karls Universität Tübingen/Geowissenschaften Fachbereich)
Creator
Troescher, Adrian
Event date
August 27, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
4476
Voltage
220
Power
41.8
Amperage
190
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000416854: M2 [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Ferreira, Gabriel
Event date
January 25, 2022
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000416854: M2 [CTImageSeries] [CT] (this media)