Media 000417031: Skull And Shoulder Girdle
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000417031
Media type
Volumetric Image Series
Object element or part
Skull and shoulder girdle
Object represented
Object taxonomy
Rhadinichthys carinatus
Object organization
Side
--
Orientation
--
Short description
Projection series for MCZ_VPF-5114
Full description
--
Creator
--
Date created
May 03, 2017
Date uploaded
January 26, 2022

FILE OBJECT DETAILS Field Definitions

File name
MCZ_VPF-5114_projections.zip
File format(s)
ZIP archive, TIFF
File size
20.8 GB
Image width
2000
Image height
2000
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Projections
X pixel spacing
0.015002
Y pixel spacing
0.015002
Z pixel spacing
0.015002
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,142

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:VP:VPF-5114 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4 seconds
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3142
Voltage
130
Power
--
Amperage
115
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
2000
Detector pixels size X
.2
Detector pixels Y
2000
Detector pixels size Y
.2
Detector configuration
--
Source object distance
83.5724830627441
Source detector distance
1114.153
Target material
Tungsten
Rotation number
--
Phase contrast
No
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000417031: Skull And Shoulder Girdle [CTImageSeries] [CT] (this media)