Media 000417177: Endocast [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000417177
Media type
Mesh
File format(s)
application/stl
File size
2.6 MB
Object element or part
Endocast
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Coen Hird
Date created
January 26, 2022
Date uploaded
January 27, 2022
Points
27,266
Polygons
54,528
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
22.248, 19.872, 32.252
Centroid coordinates
-1.939, -6.387, -22.768
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100, College of Dental Medicine (Western University of Health Sciences)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Mammals:M-33614
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100
Device facility
College of Dental Medicine (Western University of Health Sciences)
Creator
Kraatz, Brian
Date
2014-02-01
Software
--
Description
CT scan of cranium
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
Cu 0.2mm
Exposure time
9.3
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
75
Power
--
Amperage
3
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000416601: Cranium [CTImageSeries] [CT]
.
Processing Details
Creator
Kraatz, Brian
Date processed
2014-02-01
Software
i-Dixel
Description
Volumetric reconstruction
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000416601: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000417177: Endocast [Mesh] [CT]
(this media).
Processing Details
Creator
Coen Hird
Date processed
--
Software
Mimics
Description
Endocast created from CT imaging
Description attachment
None
Media produced by this event on MorphoSource

Media 000417177: Endocast [Mesh] [CT] (this media)