Media 000417195: Endocast
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000417195: Endocast
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
· Public
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000417195
Media type
Mesh
Object element or part
Endocast
Object represented
Object taxonomy
Bunolagus monticularis
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Coen Hird
Date created
January 26, 2022
Date uploaded
January 27, 2022
FILE OBJECT DETAILS Field Definitions
File name
Bunolagus_monticularis_56905_endocast.stl
File format(s)
STL
File size
2.7 MB
Points
28286
Polygons
56568
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
27.037, 23.676, 42.567
Centroid coordinates
-2.073, 19.493, -17.041
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100, College of Dental Medicine (Western University of Health Sciences)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
Museum of Comparative Zoology, Harvard University
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
MCZ:Mamm:56905
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100
Device facility
College of Dental Medicine (Western University of Health Sciences)
Creator
Kraatz, Brian
Event date
April 12, 2014
Software
i-Dixel
Description
CT scan of cranium
Description attachment
None
Reference attachment
None
Exposure time
9.3
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
75
Power
--
Amperage
3
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000416805: Cranium [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Kraatz, Brian
Event date
April 12, 2014
Software
i-Dixel
Description
Volumetric reconstruction
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000416805: Cranium [CTImageSeries] [CT]
was processed
to create
derived
Media 000417195: Endocast [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Coen Hird
Event date
--
Software
Mimics
Description
Endocast created from CT imaging
Description attachment
None
Media produced by this event on MorphoSource
Media 000417195: Endocast [Mesh] [CT] (this media)