Media 000417198: Endocast [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000417198
Media type
Mesh
File format(s)
application/stl
File size
3.15 MB
Object element or part
Endocast
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Coen Hird
Date created
January 26, 2022
Date uploaded
January 27, 2022
Points
33,032
Polygons
66,044
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
29.277, 26.076, 45.281
Centroid coordinates
-3.035, 20.291, -18.824
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100, College of Dental Medicine (Western University of Health Sciences)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-146663 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Morita Veraviewepocs 3D R100
Device facility
College of Dental Medicine (Western University of Health Sciences)
Creator
Kraatz, Brian
Date
2014-02-01
Software
i-Dixel
Description
CT scan of cranium
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
Cu 0.2mm
Exposure time
9.4
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
75
Power
--
Amperage
3
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000416775: Cranium [CTImageSeries] [CT] .

Processing Details

Creator
Kraatz, Brian
Date processed
2014-02-01
Software
i-Dixel
Description
Volumetric reconstruction
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000416775: Cranium [CTImageSeries] [CT] was processed to create derived Media 000417198: Endocast [Mesh] [CT] (this media).

Processing Details

Creator
Coen Hird
Date processed
--
Software
Mimics
Description
Endocast created from CT imaging
Description attachment
None

Media produced by this event on MorphoSource


Media 000417198: Endocast [Mesh] [CT] (this media)