Media 000426978: Skeleton [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000426978
Media type
CTImageSeries
Object element or part
skeleton
Side
--
Orientation
--
Short description
zipped 16 bit tiff stack
Full description
Al calibration
Creator
Gage, Matt
Date created
February 28, 2022
Date uploaded
February 28, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
2.81 GB
Image width
1290
Image height
200
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.027502
Y pixel spacing
0.027502
Z pixel spacing
0.027502
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,944

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273, Museum of Comparative Zoology Scanning Facility (Harvard University)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Restricted Download
IP holder
President and Fellows of Harvard College (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; overt TCN; NSF DBI-1702263
Publisher
Museum of Comparative Zoology, Harvard University
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:R-4239 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1273
Device facility
Museum of Comparative Zoology Scanning Facility (Harvard University)
Creator
Gage, Matt
Date
February 28, 2022
Software
NRecon
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
.420
Flux normalization
No
Pixel spacing calibration
Geometry
Shading correction
No
Frame averaging
3
Projections
1086
Voltage
70
Power
--
Amperage
214
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000426978: Skeleton [CTImageSeries] [CT] (this media).

Processing Details

Creator
Gage, Matt
Date processed
February 28, 2022
Software
Bruker NRecon
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000426978: Skeleton [CTImageSeries] [CT] (this media)