Media 000428535: Dentary With M1 M3 [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000428535
Media type
CTImageSeries
Object element or part
dentary with m1-m3
Side
Left
Orientation
--
Short description
paratype of Pliotomodon primitivus
Full description
--
Creator
Holroyd, Patricia A.
Date created
September 10, 2021
Date uploaded
March 06, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
3.4 GB
Image width
856
Image height
1257
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.005010
Y pixel spacing
0.005010
Z pixel spacing
0.005010
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,939

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m 180, Functional Anatomy and Vertebrate Evolution Laboratory (University of California Berkeley)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
University of California Museum of Paleontology; University of California Regents
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
Doris O. and Samuel P. Welles Fund of the University of California Museum of Paleontology; University of California Dept. of Integrative Biology; FAVE/Tseng Lab
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCMP:V:37535 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m 180
Device facility
Functional Anatomy and Vertebrate Evolution Laboratory (University of California Berkeley)
Creator
Holroyd, Patricia A.
Date
September 10, 2021
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000428535: Dentary With M1 M3 [CTImageSeries] [CT] (this media).

Processing Details

Creator
Holroyd, Patricia A.
Date processed
September 10, 2021
Software
--
Description
--
Description attachment
None

Processing Activity 1: Crop

Software
ImageJ
Description

Media produced by this event on MorphoSource


Media 000428535: Dentary With M1 M3 [CTImageSeries] [CT] (this media)