Media 000433651: Head
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

GENERAL DETAILS Field Definitions

Media ID
000433651
Media type
Volumetric Image Series
Object element or part
head
Object taxonomy
Valenciennea strigata
Side
--
Orientation
--
Short description
oVert #03653
Full description
diceCT scan. Stained in 3% Lugol's iodine for 2 weeks.
Creator
Jonathan Huie
Date created
--
Date uploaded
April 01, 2022

FILE OBJECT DETAILS Field Definitions

File name
Valenciennea_strigata_diceCT_Large.zip
File format(s)
ZIP archive, BMP
File size
1.94 GB
Image width
1533
Image height
1269
Color space
--
Color depth
8
Compression
BI_RGB; 0; None
X pixel spacing
0.013854
Y pixel spacing
0.013854
Z pixel spacing
0.013854
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,119

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714; NSF DBI-1701665
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UWFC:ADULT COLLECTION:UW 007439 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Jonathan Huie
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.150
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000433651: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Jonathan Huie
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000433651: Head [CTImageSeries] [CT] (this media)