Media 000435232: Epiplastron
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000435232
Media type
Mesh
Object element or part
Epiplastron
Object represented
Object taxonomy
Tongemys enigmatica
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Yann Rollot
Date created
December 03, 2021
Date uploaded
April 13, 2022

FILE OBJECT DETAILS Field Definitions

File name
Epiplastron_right_Tongemys_enigmatica_NHMUK_PV_OR_48262.ply
File format(s)
PLY
File size
6.91 MB
Points
104791
Polygons
209577
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
27534.398, 3941.400, 22075.000
Centroid coordinates
51402.202, 26711.580, 120957.740
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, NHMUK Imaging and Analysis Centre (The Natural History Museum, London)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
IP holder
The Trustees of the Natural History Museum, London
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:pal:PV OR 48262 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
NHMUK Imaging and Analysis Centre (The Natural History Museum, London)
Creator
Vincent Fernandez
Event date
October 08, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
250
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
4476
Voltage
215
Power
--
Amperage
660
Surrounding material
--
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
358.7 mm
Source detector distance
619.4 mm
Target material
Tungsten
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000435223: Carapace And Plastron [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000435223: Carapace And Plastron [CTImageSeries] [CT] was processed to create derived Media 000435232: Epiplastron [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Yann Rollot
Event date
December 03, 2021
Software
Amira
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000435232: Epiplastron [Mesh] [CT] (this media)