Media 000435765: Liver [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
14 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000435765
Media type
Mesh
Object element or part
liver
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Jaimi Gray
Date created
April 20, 2022
Date uploaded
April 20, 2022
FILE OBJECT DETAILS
File format(s)
application/ply
File size
25.1 MB
Points
813,034
Polygons
271,012
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
77.236, 27.142, 35.668
Centroid coordinates
-7.823, -8.926, 12.166
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Herp:182476
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Date
November 03, 2021
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000435676: Dicect Whole Body [CTImageSeries] [CT]
.
Processing Details
Creator
Jaimi Gray
Date processed
November 03, 2021
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000435676: Dicect Whole Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000435765: Liver [Mesh] [CT]
(this media).
Processing Details
Creator
Jaimi Gray
Date processed
April 20, 2022
Software
VG Studio Max and Blender
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000435765: Liver [Mesh] [CT] (this media)