Media 000442074: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000442074
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Sylvilagus floridanus
Side
--
Orientation
--
Short description
HRXCT scan - skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1288 Ekdale: sylvi: Scans of the cranium of Sylvilagus floridanus (TMM M-2329; Travis Co., TX, Brackenride Tract) for Eric Ekdale of The University of Texas Department of Geological Sciences. Specimen scanned by Matthew Colbert 9 August 2005. 16bit: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, no offset, air wedge, slice thickness 1 line (= 0.03433 mm), S.O.D. 100 mm, 1200 views, 2 samples per view, inter-slice spacing 1 line (= 0.03433 mm), field of reconstruction 30 mm (maximum field of view 32.77 mm), reconstruction offset 5000, scanner scale 4200, reconstruction scale 1400. Acquired with 25 slices per rotation. Drift- and ring removal processing done by Alison Mote based on correction of raw sinogram data using IDL routine “RK_SinoDeDrift” with parameter “driftlenth=21” and “RK_SinoRingProcSimul,” with default parameters. Reconstructed with an angle of -10 degrees. Rotation correction processing done by Alison Mote using IDL routine “DoRotationCorrection.” Total slices = 325.
Creator
Matthew Colbert
Date created
August 09, 2005
Date uploaded
May 13, 2022

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
329 MB
Image width
906
Image height
708
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.029300
Y pixel spacing
0.029300
Z pixel spacing
0.034330
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
325

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:2329 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000442074: Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000442074: Skull [CTImageSeries] [CT] (this media)