Media 000444598: Head
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000444598
Media type
Mesh
Object element or part
head
Object represented
Object taxonomy
Tropidodipsas annulifera
Object organization
Side
--
Orientation
--
Short description
--
Full description
mesh from microCT volume, data inverted following CT scan
Creator
Braker, Emily
Date created
--
Date uploaded
May 26, 2022

FILE OBJECT DETAILS Field Definitions

File name
UCM_Herp_64595_Tropidodipsas_annulifera_head_mesh.stl
File format(s)
STL
File size
1.66 GB
Points
4916439
Polygons
9794068
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.797, 21.183, 9.445
Centroid coordinates
-10.019, -29.113, -9.047
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Colorado Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oMeso PEN NSF DBI-2001474; oVert TCN partner NSF DBI-1701714
Publisher
University of Colorado Museum of Natural History
Cite as
UCM Herp [catalog number]
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCM:Herp:UCM:Herp:64595 was imaged to create raw Media 000444592: Head [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm)
Device facility
Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
Creator
--
Event date
--
Software
Scout-and-Scan Control System
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.799999952
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
1
Projections
1601
Voltage
120
Power
0.01
Amperage
75
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
tungsten
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000444592: Head [CTImageSeries] [CT] was processed to create derived Media 000444598: Head [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
Dragonfly
Description
Reconstructed tomography to mesh, with smoothing and noise reduction
Description attachment
None

Media produced by this event on MorphoSource

Media 000444598: Head [Mesh] [CT] (this media)