Media 000445178: Braincase
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

GENERAL DETAILS Field Definitions

Media ID
000445178
Media type
Volumetric Image Series
Object element or part
braincase
Object represented
Object taxonomy
Europasaurus holgeri
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Zwick, Bastian ; Schade, Marco
Date created
October 26, 2021
Date uploaded
May 30, 2022

FILE OBJECT DETAILS Field Definitions

File name
Europasaurus_-_DFMMh-FV_581.1__2__3.zip
File format(s)
ZIP archive, DICOM
File size
16 GB
Image width
2502
Image height
2727
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.048799
Y pixel spacing
0.048799
Z pixel spacing
0.048790
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,804

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Metrotom 1500, Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Dinosaurierpark Münchehagen
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
Dinosaurierpark Münchehagen
Cite as
Marco Schade provided access to these data. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object DFMMh/FV 581.1, 2, 3 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Metrotom 1500
Device facility
Zeiss Competency Center for Car Body Measuring Technology Essingen (Carl Zeiss Industriellen Messtechnik GmbH)
Creator
Schade, Marco
Event date
October 26, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1000 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
220 kV
Power
--
Amperage
343 µA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000445178: Braincase [CTImageSeries] [CT] (this media)