Media 000452012: Carapace
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000452012: Carapace
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
TAGS
GENERAL DETAILS Field Definitions
Media ID
000452012
Media type
Mesh
Object element or part
Carapace
Object represented
Object taxonomy
Homopus areolatus
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Guilherme Hermanson
Date created
July 26, 2022
Date uploaded
July 26, 2022
FILE OBJECT DETAILS Field Definitions
File name
Homopus_areolatus_OUMNH_9403_Carapace.ply
File format(s)
PLY
File size
271 MB
Points
6426920
Polygons
12907912
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
64.386, 88.578, 36.262
Centroid coordinates
31.038, 55.744, 34.525
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Oxford University Museum of Natural History (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
oumnh:zc:09403
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Benson, Roger
Event date
June 25, 2019
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
500 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
110 kV
Power
--
Amperage
318 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000354264: Full Body [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Benson, Roger
Event date
June 25, 2019
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000354264: Full Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000452012: Carapace [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Guilherme Hermanson
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000452012: Carapace [Mesh] [CT] (this media)