Media 000454832: Partial Skull
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000454832: Partial Skull
Restricted Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS
Media ID
000454832
Media type
CT Image Series
Object element or part
partial skull
Object represented
Object taxonomy
Ecteninion lunensis
Object organization
Side
--
Orientation
--
Short description
HRXCT scan of partial skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0215
Rowe/ecten:
Scans of the skull and lower jaws of Ecteninion lunensis n. sp. (Museo de Ciencias Naturales, Universidad Nacional de San Juan # PVSJ 422) for Dr. Timothy Rowe of University of Texas, Department of Geological Sciences. Specimen is a new carnivorous eucynodont from the Late Triassic Ischigualasto Fm., San Juan Province, northwestern Argentina. Scanned by Matthew Colbert and Richard Ketcham on January 19, 2000.
Publication: R. Martinez et al. 1996. A new carnivorous cynodont from the Ischigualasto Formation (Late Triassic, Argentina), with comments on eucynodont phylogeny. Journal of Vertebrate Paleontology v.16: 271-284.
ecten: original scanned images. II, 180 kV, 0.133 mA, aluminum filter, no wedge, 160 % offset, slice thickness 3 lines (= 0.1624 mm), S.O.D. 95 mm, 600 views, 2 samples per view, interslice spacing 3 lines (= 0.1624 mm), field of reconstruction 46 mm, reconstruction offset 620, reconstruction scale 26. Scanned in three-slice mode.
Creator
Matthew Colbert and Richard Ketcham
Date created
January 19, 2000
Date uploaded
August 08, 2022
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
149 MB
Image width
512
Image height
512
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.089800
Y pixel spacing
0.089800
Z pixel spacing
0.162400
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
621
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Museo de Ciencias Naturales, Universidad Nacional de San Juan
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
imcn:PVSJ 422
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert and Richard Ketcham
Date
January 19, 2000
Software
--
Description
partial skull
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000454832: Partial Skull [CTImageSeries] [CT] (this media).
Processing Details
Creator
--
Date processed
--
Software
--
Description
--
Description attachment
None