Media 000454843: Partial Skull [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000454843
Media type
CTImageSeries
Object element or part
partial skull
Side
--
Orientation
--
Short description
HRXCT scan of partial skull
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0204 Rowe: Scans of a juvenile Probainognathus skull for Dr. Timothy Rowe of the University of Texas, Dept. Geological Sciences. Specimen information: cf. Probainognathus sp. (PVSJ 410), lower section of the Ischigualasto Formation, early Late Triassic, northwestern Argentina, collected by Andrea Arcucci (see Bonaparte, J. F., and A. W. Crompton. 1994. A juvenile probainognathid cynodont skull from the Ischigualasto Formation and the origin of mammals. Revista del Museo Argentino de Ciencias Naturales “Bernardino Rivadavia” 5: 1-12). Scanned by Richard Ketcham and Matthew Colbert on 1/14/2000. jpro: original scanned images. II, 180 kV, 0.133 mA, no filter, air wedge, 160% offset, slice thickness 4 lines (= 0.085 mm), S.O.D. 37.5 mm, 1800 views, 2 samples per view, interslice spacing 3 lines (= 0.0641 mm), field of reconstruction 18 mm, reconstruction offset 400, reconstruction scale 8. Scanned in three-slice mode.
Creator
Richard Ketcham and Matthew Colbert
Date created
January 14, 2000
Date uploaded
August 08, 2022

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
112 MB
Image width
512
Image height
512
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.035200
Y pixel spacing
0.035200
Z pixel spacing
0.064100
Pixel spacing units
Mm
Number of images in set
498

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Museo de Ciencias Naturales, Universidad Nacional de San Juan
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object imcn:PVSJ 410 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham and Matthew Colbert
Date
January 14, 2000
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000454843: Partial Skull [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000454843: Partial Skull [CTImageSeries] [CT] (this media)