Media 000471334: Humerus
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000471334
Media type
Mesh
Object element or part
Humerus
Object represented
Object taxonomy
Eleutherodactylus counouspeus
Side
Right
Orientation
--
Short description
Humerus mesh
Full description
--
Creator
Maria C Vallejo
Date created
March 14, 2021
Date uploaded
October 04, 2022

FILE OBJECT DETAILS Field Definitions

File name
Eleutherodactylus_counouspeus_UF_100966_Humerus_right.stl
File format(s)
STL
File size
7.33 MB
Points
19640
Polygons
39672
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.584, 3.063, 5.390
Centroid coordinates
-4.732, -1.785, 9.989
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:100966 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1800
Voltage
80
Power
0.016
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000058448: Whole Body [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000058448: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000471334: Humerus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Maria C Vallejo
Event date
March 14, 2021
Software
VG Studio Max 3.5
Description
Mesh
Description attachment
None

Media produced by this event on MorphoSource

Media 000471334: Humerus [Mesh] [CT] (this media)