Media 000476303: Whole Body
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000476303: Whole Body
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
Project
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000476303
Media type
Mesh
Object element or part
whole body
Object represented
Object taxonomy
Desmodus rotundus
Object organization
Side
NotApplicable
Orientation
--
Short description
bat skeleton with repositioned right wing and hindlimb
Full description
As seen on Sketchfab
Creator
Jaimi Gray
Date created
October 20, 2022
Date uploaded
October 20, 2022
FILE OBJECT DETAILS Field Definitions
File name
vampire-bat-UF-mamm-9818.ply
File format(s)
PLY
File size
124 MB
Points
3109328
Polygons
1393561
Map type
--
UV coordinates
True
Vertex color
True
Bounding box dimensions
201.429, 42.245, 136.318
Centroid coordinates
-12.161, 1.734, 1.448
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
UF:Mammals:9818
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000445804: Whole Body [CTImageSeries] [CT].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
July 13, 2018
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000445804: Whole Body [CTImageSeries] [CT]
was processed
to create
derived
Media 000476303: Whole Body [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Jaimi Gray
Event date
October 20, 2022
Software
VG Studio Max & Blender
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000476303: Whole Body [Mesh] [CT] (this media)