Media 000485927: Shell Valve
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000485927
Media type
Mesh
Object element or part
shell valve
Object represented
Object taxonomy
Trichomusculus barbatus
Side
Right
Orientation
--
Short description
--
Full description
Record created by batch submission.
Creator
Katie Collins
Date created
--
Date uploaded
November 30, 2022

FILE OBJECT DETAILS Field Definitions

File name
3512.stl
File format(s)
STL
File size
2.41 MB
Points
25308
Polygons
50616
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.314, 8.457, 5.328
Centroid coordinates
12.970, 14.897, -6.453
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Santa Barbara Museum of Natural History
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object sbmnh:622525 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Katie Collins
Event date
--
Software
Phoenix Datos|x
Description
--
Description attachment
None
Reference attachment
None
Exposure time
131
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
0
Projections
2000
Voltage
160
Power
25.6
Amperage
160
Surrounding material
--
X-ray tube type
240 kV
Target type
Reflection
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000485927: Shell Valve [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Katie Collins
Event date
--
Software
VG StudioMax
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000485927: Shell Valve [Mesh] [CT] (this media)