Media 000494577: Frontal (Right)
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000494577
Media type
Mesh
Object element or part
Frontal (Right)
Object represented
Object taxonomy
Plesiobaena sp.
Object organization
Side
Right
Orientation
--
Short description
--
Full description
3D volume rendering of frontal of BDM 004
Creator
Heather F. Smith
Date created
January 25, 2023
Date uploaded
January 26, 2023

FILE OBJECT DETAILS Field Definitions

File name
BDM_004_Frontal_R_.ply
File format(s)
PLY
File size
45.5 MB
Points
693252
Polygons
1386500
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
365.617, 441.345, 579.749
Centroid coordinates
1055.464, 1145.831, 338.925
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
2
Number of processing events
2 (0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
ZEISS Xradia 520 Versa, Chawla Research Group (Purdue University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Heather F. Smith
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Midwestern University Core Facility Funds
Publisher
Heather F. Smith
Cite as
Heather F. Smith provided access to these data originally appearing in …. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object BDM:BDM:BDM 004 was imaged to create raw Media 000474320: Cranium [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
ZEISS Xradia 520 Versa
Device facility
Chawla Research Group (Purdue University)
Creator
Heather Smith
Event date
March 05, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
10.000000
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2026
Voltage
120 V
Power
--
Amperage
84.000000
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
29.214855
Detector pixels Y
--
Detector pixels size Y
29.214855
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
Yes
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Processing Details Field Definitions

Creator
Heather F. Smith
Event date
October 12, 2022
Software
Aviso
Description
3D volume rendering of BDM 004 full cranium
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000474323: Cranium [Mesh] [CT] was processed to create derived Media 000494577: Frontal (Right) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Heather F. Smith
Event date
January 25, 2023
Software
Aviso
Description
Frontal (Right) of BDM 004
Description attachment
None

Media produced by this event on MorphoSource

Media 000494577: Frontal (Right) [Mesh] [CT] (this media)