Media 000494670: Skull Cavities Of Portugalosuchus Azenhae (Ml1818)
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)

Media Display

GENERAL DETAILS Field Definitions

Media ID
000494670
Media type
Mesh
Object element or part
Skull cavities of Portugalosuchus azenhae (ML1818)
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
January 27, 2023

FILE OBJECT DETAILS Field Definitions

File name
Endocranial_cavities_ML1818.zip
File format(s)
ZIP archive, OBJ
File size
326 MB
Points
97189
Polygons
194374
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
26.162, 22.607, 14.796
Centroid coordinates
57.762, 49.118, 140.686
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, Microscopy and Micro-CT Laboratory (Centro Nacional de Investigación sobre la Evolución Humana, CENIEH)

OWNERSHIP AND PERMISSIONS Field Definitions

Publication status
Restricted Download
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ML:ML1818 3 D Segmentation Of The Skull Cavities Of The Holotype Ml1818 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
Microscopy and Micro-CT Laboratory (Centro Nacional de Investigación sobre la Evolución Humana, CENIEH)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
170 kV
Power
--
Amperage
250 μA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000494670: Skull Cavities Of Portugalosuchus Azenhae (Ml1818) [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000494670: Skull Cavities Of Portugalosuchus Azenhae (Ml1818) [Mesh] [CT] (this media)