Media 000494757: Dentary
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000494757: Dentary
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000494757
Media type
Mesh
Object element or part
Dentary
Object represented
Object taxonomy
Tinosarus europeocaenus
Object organization
Side
Left
Orientation
--
Short description
Left dentary
Full description
Left dentary
Creator
Andrej Čerňanský
Date created
January 18, 2023
Date uploaded
January 30, 2023
FILE OBJECT DETAILS Field Definitions
File name
IRSNB_R_0202bis_Tinosaurus_europeoceanus.ply
File format(s)
PLY
File size
214 MB
Points
2949882
Polygons
5899000
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
1.211, 2.290, 10.793
Centroid coordinates
4.310, 4.338, 6.215
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150, Scanning Facilities of RBINS Scientific Survey of Heritage (SSH) (Royal Belgian Institute of Natural Sciences)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Belspo BRAIN project BR/121/A3/PALEURAFRICA (to T. S.) funded by the Belgian Science Policy Office; the Scientific Grant Agency of the Ministry of Education of Slovak Republic and Slovak Academy of Sciences, Grant Nr. 1/0191/21 (to A. Č); SYNTHESYS project BE-TAF-8234 (to A. Č) funded by the European Commission (http://www.synthesys.info/)
Publisher
--
Cite as
Čerňanský et al., 2023
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
RBINS-Scientific Heritage:R:202 bis
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150
Device facility
Scanning Facilities of RBINS Scientific Survey of Heritage (SSH) (Royal Belgian Institute of Natural Sciences)
Creator
Camille Locatelli
Event date
January 18, 2023
Software
--
Description
Left dentary
Description attachment
None
Reference attachment
None
Exposure time
400 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
85 Kv
Amperage
77
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000494757: Dentary [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Andrej Čerňanský
Event date
--
Software
Avizo 8.1
Description
Left dentary
Description attachment
None
Media produced by this event on MorphoSource
Media 000494757: Dentary [Mesh] [CT] (this media)