Media 000574507: Dice Ct
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS

Media ID
000574507
Media type
Volumetric Image Series
Object element or part
diceCT
Object represented
Object taxonomy
Ostracoberyx dorygenys
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Record created by batch submission.
Creator
Jaimi Gray
Date created
--
Date uploaded
October 26, 2023

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
3.18 GB
Image width
1510
Image height
1269
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.025748
Y pixel spacing
0.025748
Z pixel spacing
0.025748
Pixel spacing units
Mm
Slice thickness
0.02574788
Number of images in set
4,101

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object VIMS:VIMS:42878 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Jaimi Gray
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
200.098
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
2040
Voltage
100
Power
0.02
Amperage
200
Surrounding material
air
Xray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
2024
Detector pixel size X
0.2
Detector pixels Y
2024
Detector pixel size Y
0.2
Detector configuration
Area (single or tiled detector)
Source object distance
103.3488125
Source detector distance
802.77534791
Target material
tungston
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000574507: Dice Ct [CTImageSeries] [CT] (this media).

Processing Details

Creator
Jaimi Gray
Date processed
--
Software
DatosX|R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000574507: Dice Ct [CTImageSeries] [CT] (this media)